TLP-8012A5 -
High Power Pulse Instruments GmbH
*Pulse width extender for the high current TLP/HMM test system TLP-8010A and TLP-8010C*6 manual selectable pulse width: 5, 10, 50, 100, 200 and 500 ns*High pulse output current up to ±80 A*High performance and high quality components
-
TLP-3011C -
High Power Pulse Instruments GmbH
*Fully automatic pulsewidth extender*Pulse width up to 1.6 µs in 68 programmable steps of 25 ns*Ultra fast 50 Ω pulsewidth extension with typical 100 ps rise time*High pulse output current up to ±40 A*High performance and high quality components
-
TLP-12012A6 -
High Power Pulse Instruments GmbH
- Pulse width extender for the high current TLP/HMM test system TLP-12010A and TLP-12010C- 6 manual selectable pulse width: 5, 10, 50, 100, 200 and 500 ns- High pulse output current up to ±120 A- High performance and high quality components
-
785033-01 -
NI
2-Channel, 100 MHz PXI Pulse Generator - The Astronics PXIe-1209 provides dual independent pulse generation with full control of all timing parameters with extremely high resolution. Both channels are fully independent, and you can configure pulse delay, double pulse spacing, pulse width, and period. Each channel offers front panel trigger inputs with software-programmable thresholds and PXI backplane triggering.
-
PXIe-1209 -
Astronics Corporation
The Astronics Test Systems PXIe-1209 PXI is a high-performance, 2-channel, 100 MHz Pulse Generator. Occupying a single PXI Express peripheral slot or hybrid slot, the PXIe-1209 provides dual independent pulse generation with fullcontrol of all timing parameters with extremely high resolution.
-
3172 -
Astronics Corporation
The Racal Instruments™ 3172, a 200 MS/s Waveform Generator and Dual 50 MHz Pulse and Timing Generator, combines multi-instrument density and highfrequency performance in a single-slot, C-sized VXIbus format.Waveform output in the range of 100 μHz to 30 MHz with 16-bit vertical resolution (12-bit vertical for 3171 emulation) and pulse output to 50 MHz make the 3172 a powerful solution to a variety of test stimulus requirements.
-
Laurel Electronics, Inc
The Laureate? time interval meter can display pulse width or time delay between individual pulses to a resolution of 0.2 s. It can also display average pulse width or average time delay between multiple pulses.
-
DP-VME-5835 -
Data Patterns Pvt. Ltd.
DP- VME-5835 is a Pulse Width Modulator module with analog outputs. This module has thirty two Pulse Width Modulated output channels and four analog output channels.
-
ADC Corporation
Pulse generation/measurement with basic accuracy of ±0.02% and the minimum pulse width of 50μs, maximum output of 6V/5A
-
Minioptic Technology, Inc
Opticala Autocorrelators are devices for measuring the intensity or field autocorrelation function of light, mostly used for determining the pulse width of picosecond or femtosecond pulses, to which an electronic apparatus such as oscillascope would be too slow. The basic principle of operation of an autocorrelator for a pulse width measurement is to check the correlation of the temporal pulse trace with itself.
-
TLP-8010C -
High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns (0-40 A), 1 built-in pulse width: 100 ns (> 40 A)*The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0-40 A)*Optional external pulse width extensions from 5 ns to 500 ns (> 40…80 A) using the external pulse width extender TLP-8012A5*Built-in pulse reflection suppression*Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components
-
APC464 -
Acromag, Inc.
Four 16-bit multifunction counters/timers are configurable for pulse width modulated output, watchdog timer, event counter, frequency measurement, pulse width measurement, period measurement, or one shot pulse output. The four 16-bit counters can also be configured into two 32-bit counter/timers.
-
TLP-12010C -
High Power Pulse Instruments GmbH
- High pulse output current up to 120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical rise time 100 ps (0 A to 40 A) and 300 ps in high-current mode (0 A to 120 A)- Wafer, package and system level TLP, VF-TLP and HMM testing- Up to 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 USB programmable pulse rise times: 100 ps to 50 ns (custom selectable)- 8 (optional 9) programmable pulse widths: 0.5 ns (optional), 1 ns to 100 ns (0 A to 40 A), 1 built-in pulse width: 100 ns (>40 A)- The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0 A to 40 A)- Optional external pulse width extensions from 5 ns to 500 ns (>40 A to 120 A)using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient sofware for system control and waveform data management- The sofware can control automatic probers for fast measurements of complete wafers- Combines TLP-12010A and TLP-4010C into one system- Can be operated together with TLP-12012A6 and TLP-3011C pulse width extenders- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface
-
Reef -
Del Mar Photonics, Inc.